Current Electricity and Magnetism – Thermoelectric MCQ questions with answers
CEE Entrance · Physics. Below are 10 sample questions from this chapter, each with the correct answer and an explanation. The full set of 256 questions is free to practise on Prashnalaya.
Topics covered: Peltier effect: concept and applications, Seebeck effect: concept and applications, Thermocouple: working and calculations
- Q1.Arrange the following thermocouple materials in increasing order of thermoelectric power relative to lead near room temperature: Iron, Antimony, Copper, Bismuth.
- A.Copper
- B.Bismuth
- C.Iron
- D.Antimony
Show answer and explanation
Answer: A. Copper, B. Bismuth, C. Iron, D. Antimony
In the thermoelectric series near room temperature, bismuth lies lower than antimony, antimony lies lower than copper, and copper lies lower than iron. Therefore, the increasing order of thermoelectric power is Bismuth < Antimony < Copper < Iron. - Q2.A copper-iron thermocouple has a cold junction at and a hot junction at . Arrange the following steps in the correct order to calculate the emf when the neutral temperature is known and the temperature difference is below the neutral temperature range.
- A.Use , substitute , then calculate emf
- B.Identify the hot junction temperature relative to the cold junction, write the thermocouple emf relation, then substitute constants
- C.Write the inversion temperature first, then divide by 2, then use the result directly as emf
- D.Take the average temperature of both junctions, square it, then subtract the cold junction temperature
Show answer and explanation
Answer: B. Identify the hot junction temperature relative to the cold junction, write the thermocouple emf relation, then substitute constants
For a thermocouple with a cold junction at , the working temperature difference is simply the hot junction temperature . The correct method is: identify the temperature difference, write the relation , and then substitute the given constants to find emf. The other options confuse inversion temperature, average temperature, or incorrect steps. - Q3.Arrange the temperatures for a thermocouple in the correct physical sequence from lowest to highest when the thermoelectric emf first becomes maximum and then falls to zero on further heating: cold junction temperature, neutral temperature, inversion temperature, very high hot-junction temperature beyond inversion.
- A.neutral temperature
- B.very high hot-junction temperature beyond inversion
- C.cold junction temperature
- D.inversion temperature
Show answer and explanation
Answer: A. neutral temperature, B. very high hot-junction temperature beyond inversion, C. cold junction temperature, D. inversion temperature
In a thermocouple, emf starts from zero when both junctions are at the same temperature. As the hot junction temperature rises above the cold junction temperature, emf increases and reaches maximum at the neutral temperature. On further heating, emf decreases and becomes zero at the inversion temperature. Beyond inversion, the emf reverses direction. So the correct order is cold junction temperature < neutral temperature < inversion temperature < very high hot-junction temperature. - Q4.For a thermocouple with emf relation where is negative, arrange the following steps in the correct order to find the neutral temperature from experimental constants and .
- A.Substitute directly, then differentiate to verify, then set emf to zero
- B.Differentiate emf with respect to , set , solve for , then interpret it as temperature of maximum emf
- C.Set , solve for two roots, choose the larger root, then call it neutral temperature
- D.Multiply emf by temperature, equate to a constant, then solve a quadratic in
Show answer and explanation
Answer: B. Differentiate emf with respect to , set , solve for , then interpret it as temperature of maximum emf
The neutral temperature is the temperature at which thermoelectric emf is maximum. So we differentiate: . For maximum emf, set , giving or . This is the correct sequence. Setting gives inversion-related roots, not neutral temperature. - Q5.A thermocouple is used to measure furnace temperature. Arrange the following events in the correct order of operation for practical temperature measurement: keep one junction at known reference temperature, place the other junction in the furnace, produce thermoelectric emf, compare the emf with calibration to find temperature.
- A.Produce thermoelectric emf
- B.Compare the emf with calibration to find temperature
- C.Keep one junction at known reference temperature
- D.Place the other junction in the furnace
Show answer and explanation
Answer: A. Produce thermoelectric emf, B. Compare the emf with calibration to find temperature, C. Keep one junction at known reference temperature, D. Place the other junction in the furnace
In practical use, the cold junction is first maintained at a known reference temperature. Then the hot junction is placed in the furnace. Due to temperature difference, thermoelectric emf is produced. Finally, this emf is compared with the calibration chart or formula to determine the furnace temperature. This is the correct operational sequence. - Q6.A thermocouple is used as a temperature sensor. Arrange the steps from construction to temperature reading. Join two dissimilar metal wires to form two junctions. Keep one junction at reference temperature. Place the other junction at the unknown temperature. Measure the produced thermo-emf and infer the temperature.
- A.Measure the produced thermo-emf and infer the temperature
- B.Keep one junction at reference temperature
- C.Join two dissimilar metal wires to form two junctions
- D.Place the other junction at the unknown temperature
Show answer and explanation
Answer: A. Measure the produced thermo-emf and infer the temperature, B. Keep one junction at reference temperature, C. Join two dissimilar metal wires to form two junctions, D. Place the other junction at the unknown temperature
$A thermocouple works on the Seebeck effect: when two dissimilar metals form two junctions kept at different temperatures, a thermo-emf is produced. To use it as a temperature sensor, the steps must follow the physical setup and then the measurement process.
Step 1: Join two dissimilar metal wires to form two junctions.
This is the construction of the thermocouple. Without forming the two junctions, the device cannot work.
Step 2: Keep one junction at reference temperature.
One junction is maintained at a known temperature, called the reference or cold junction. This provides the comparison point needed for measurement.
Step 3: Place the other junction at the unknown temperature.
The second junction, called the hot junction or measuring junction, is placed where the temperature is to be measured.
Step 4: Measure the produced thermo-emf and infer the temperature.
Because of the temperature difference between the two junctions, an emf is generated. By measuring this thermo-emf and using calibration data, the unknown temperature is determined.
So the correct order is:
1. Join two dissimilar metal wires to form two junctions
2. Keep one junction at reference temperature
3. Place the other junction at the unknown temperature
4. Measure the produced thermo-emf and infer the temperature$ - Q7.For a thermocouple with a positive Seebeck coefficient, arrange the quantities in increasing order when the temperature difference is slowly increased from zero, up to the neutral temperature, and then beyond it. Thermo-emf is zero at zero temperature difference. Thermo-emf increases with temperature difference. Thermo-emf becomes maximum at neutral temperature. Thermo-emf decreases after neutral temperature and may become zero at inversion temperature.
- A.Thermo-emf decreases after neutral temperature and may become zero at inversion temperature
- B.Thermo-emf is zero at zero temperature difference
- C.Thermo-emf becomes maximum at neutral temperature
- D.Thermo-emf increases with temperature difference
Show answer and explanation
Answer: A. Thermo-emf decreases after neutral temperature and may become zero at inversion temperature, B. Thermo-emf is zero at zero temperature difference, C. Thermo-emf becomes maximum at neutral temperature, D. Thermo-emf increases with temperature difference
For a thermocouple with positive Seebeck coefficient, the thermo-emf depends on the temperature difference between the junctions. As the hot-junction temperature is raised gradually from zero temperature difference:
1. At zero temperature difference, there is no thermoelectric effect, so thermo-emf is zero.
2. When the temperature difference starts increasing, thermo-emf increases.
3. At the neutral temperature, thermo-emf reaches its maximum value.
4. If the temperature difference is increased further beyond the neutral temperature, thermo-emf decreases and can finally become zero at the inversion temperature.
So the correct increasing sequence of events is:
- Thermo-emf is zero at zero temperature difference
- Thermo-emf increases with temperature difference
- Thermo-emf becomes maximum at neutral temperature
- Thermo-emf decreases after neutral temperature and may become zero at inversion temperature
This matches the marked order, so no correction is needed. - Q8.Arrange the following thermoelectric effects according to the historical and conceptual development from basic observation to combined device operation. Seebeck effect: temperature difference produces emf Peltier effect: electric current causes heating or cooling at a junction Thomson effect: current in a conductor with temperature gradient absorbs or evolves heat Thermoelectric module uses these principles in sensing or cooling applications
- A.Peltier effect: electric current causes heating or cooling at a junction
- B.Thermoelectric module uses these principles in sensing or cooling applications
- C.Seebeck effect: temperature difference produces emf
- D.Thomson effect: current in a conductor with temperature gradient absorbs or evolves heat
Show answer and explanation
Answer: A. Peltier effect: electric current causes heating or cooling at a junction, B. Thermoelectric module uses these principles in sensing or cooling applications, C. Seebeck effect: temperature difference produces emf, D. Thomson effect: current in a conductor with temperature gradient absorbs or evolves heat
The correct order is from the earliest/basic thermoelectric observation to later related effects and finally practical application.
1. Seebeck effect: temperature difference produces emf
This is the foundational thermoelectric effect. Seebeck discovered that when two dissimilar conductors form a circuit and their junctions are kept at different temperatures, an emf is produced. This is the basic principle behind thermocouples.
2. Peltier effect: electric current causes heating or cooling at a junction
This came next conceptually as the reverse of the Seebeck effect. Instead of temperature difference producing voltage, an electric current passed through the junction of two different conductors causes heat absorption or heat release.
3. Thomson effect: current in a conductor with temperature gradient absorbs or evolves heat
This is a further thermoelectric effect involving a single conductor. When current flows through a conductor that already has a temperature gradient, heat may be absorbed or evolved along the conductor. It completes the set of the three main thermoelectric effects.
4. Thermoelectric module uses these principles in sensing or cooling applications
After understanding the basic effects, practical devices are developed. Thermoelectric modules use these principles in real applications such as temperature sensing, power generation, and cooling.
So the proper developmental sequence is:
Seebeck effect Peltier effect Thomson effect Thermoelectric module.
The originally marked order is correct, so no change is needed. - Q9.Arrange the stages involved in using the Seebeck effect in a thermoelectric generator for waste-heat recovery. A hot source and a cold sink create a temperature difference across thermocouples. Seebeck emf is generated in each thermocouple pair. Several thermocouples are connected to obtain useful output voltage. Electrical energy is delivered to an external load.
- A.Electrical energy is delivered to an external load
- B.Several thermocouples are connected to obtain useful output voltage
- C.A hot source and a cold sink create a temperature difference across thermocouples
- D.Seebeck emf is generated in each thermocouple pair
Show answer and explanation
Answer: A. Electrical energy is delivered to an external load, B. Several thermocouples are connected to obtain useful output voltage, C. A hot source and a cold sink create a temperature difference across thermocouples, D. Seebeck emf is generated in each thermocouple pair
$The marked order is correct.
A thermoelectric generator works on the Seebeck effect, which states that when two dissimilar conductors or semiconductors form a circuit and their junctions are kept at different temperatures, an emf is produced.
Step-by-step sequence:
1. First, a hot source and a cold sink create a temperature difference across the thermocouples.
- This temperature gradient is the basic requirement for the Seebeck effect.
- Without a temperature difference, no thermoelectric emf is generated.
2. Due to this temperature difference, Seebeck emf is generated in each thermocouple pair.
- Each thermocouple develops a small voltage.
- The magnitude depends on the materials used and the temperature difference.
3. Several thermocouples are connected to obtain useful output voltage.
- A single thermocouple produces only a small emf.
- Therefore, many thermocouples are connected, usually in series electrically, so their voltages add up to a practical value.
4. Finally, electrical energy is delivered to an external load.
- Once sufficient voltage is available, the generator can supply electrical power to a connected device or circuit.
So the correct order is:
1. A hot source and a cold sink create a temperature difference across thermocouples
2. Seebeck emf is generated in each thermocouple pair
3. Several thermocouples are connected to obtain useful output voltage
4. Electrical energy is delivered to an external load$ - Q10.Arrange the following quantities or ideas in the correct sequence to express the relation for heat produced or absorbed in the Peltier effect.
Peltier coefficient of the junction
Charge passing through the junction
Product giving Peltier heat
Expression is identified in concept form- A.Charge passing through the junction
- B.Product giving Peltier heat
- C.Peltier coefficient of the junction
- D.Expression is identified in concept form
Show answer and explanation
Answer: A. Charge passing through the junction, B. Product giving Peltier heat, C. Peltier coefficient of the junction, D. Expression is identified in concept form
In the Peltier effect, the basic relation is that the heat produced or absorbed at a junction is proportional to the charge passing through it. Mathematically, this is written as
where:
- = heat produced or absorbed,
- = Peltier coefficient of the junction,
- = charge passing through the junction.
Also, the Peltier coefficient is defined as heat per unit charge:
So the logical sequence is:
1. First identify the concept of heat per unit charge, i.e. the expression in conceptual form. This points to the definition of the Peltier coefficient.
2. Then comes the Peltier coefficient of the junction.
3. Next consider the charge passing through the junction.
4. Finally, taking the product of coefficient and charge gives the Peltier heat.
Thus the correct order is:
- Expression is identified in concept form
- Peltier coefficient of the junction
- Charge passing through the junction
- Product giving Peltier heat
Hence the marked answer is correct.
Practise all 256 Current Electricity and Magnetism – Thermoelectric questions
Instant feedback, explanations, timed mock tests and progress tracking. Free on the web and Android.
More Physics chapters
- Current Electricity and Magnetism – AC MCQs348
- Current Electricity and Magnetism – Circuits MCQs472
- Current Electricity and Magnetism – Electrical Quantities MCQs313
- Current Electricity and Magnetism – Electromagnetic Induction MCQs472
- Current Electricity and Magnetism – Magnetic Field MCQs470
- Current Electricity and Magnetism – Magnetic Materials MCQs204
- Electrostatics and Capacitors MCQs972
- Heat and Thermodynamics MCQs1,486
- Mechanics – Circular & Periodic Motion MCQs566
- Mechanics – Dynamics MCQs670
- Mechanics – Elasticity MCQs279
- Mechanics – Fluid Statics & Dynamics MCQs755
- Mechanics – Gravity MCQs497
- Mechanics – Kinematics MCQs362
- Mechanics – Physical Quantities & Vectors MCQs382
- Mechanics – Rotational Dynamics MCQs378
- Modern Physics – Electron MCQs390
- Modern Physics – Nuclear Physics MCQs481
- Modern Physics – Particle Physics & Recent Trends MCQs394
- Modern Physics – Photon MCQs312
- Modern Physics – Radioactivity MCQs498
- Modern Physics – Semiconductors MCQs485
- Modern Physics – Wave-Particle Duality MCQs582
- Waves and Optics – Acoustics MCQs310
- Waves and Optics – Diffraction & Polarization MCQs436
- Waves and Optics – Interference MCQs202
- Waves and Optics – Reflection & Refraction MCQs412
- Waves and Optics – Stationary Waves MCQs304
- Waves and Optics – Wave Motion MCQs368
